Page 111 - Demo
P. 111
Find out more at baxi.co.uk/professional/products/commercial-heating-and-hot-water-solutionsBESA 2023 performance data AquaHeatHI / HWI %u2013 4/50 with Heat Meter & MercuriusAquaHeat HI / HWI %u2013 4/50AquaHeat HI / HWI %u2013 14/50 with Heat Meter & MercuriusAquaHeat HI / HWI %u2013 14/50AquaHeat HI-50 with Heat Meter & MercuriusAquaHeat HI-50Product code 7867470 7867472 7867476 7867477 7867474 7867475Hydraulic informationMax Primary operating pressure %u2013 bar g16 16 16 16 16 16Max Primary operating temperature %u2013 %u00b0C90 90 90 90 90 90Max Secondary operating pressure %u2013 bar g2.5 2.5 2.5 2.5 3 3Max Secondary operating temperature %u2013 %u00b0C85 85 85 85 85 85Max operating pressure DHW %u2013 bar g10 10 10 10 - -Min cold mains water supply pressure %u2013 bar g1 1 1 1 - -Space heating set point %u2013 %u00b0C 45 45 45 45 45 45DHW set point %u2013 %u00b0C 50 50 50 50 - -GeneralDimensions %u2013 W x H x D (mm) 540 x 750 x 260540 x 750 x 260540 x 750 x 260540 x 750 x 260540 x 857 x 260540 x 857 x 260Weight (dry) (kg) 27 26.5 27 26.7 30 30Clearances**Front (mm) 200 200 200 200 200 200Rear (mm) 100 100 100 100 100 100Left / right (mm) 30 30 30 30 30 30Top (mm) 100 100 100 100 100 100Baxi Packaged Solutions 111